Controller (PZA )
AC sequence controller
The AtlasIED TSD-SEQ6 sequencer controller features 6 outputs that can be individually configured to be either a 24 VDC output or hard switch contact closure (DC). There are two separate output sequence time delay regulators ranging from 1 second to 10 minutes. Activation can be done via the front panel or remotely via DC Hard Switch, momentary switch or DC voltage. The TSD-SEQ6 also incorporates an Emergency Power Off (EPD) port for local fire codes. You can link two TSD-SEQ6 units to obtain 12 sequenced outputs.
The unit requires a power supply sold separately to operate properly; multiple TSDs can be powered with one power supply depending on current requirements. This unit has a 100mA power requirement, so any of the TSD power supplies available with the unit can be used. For multiple TSD applications, use the TSD Energy Calculator to determine the appropriate power supply needed.
CHARACTERISTICS:
-
6 sequenced outputs
-
Hard switch contact closure (DC) assignable 24 VDC or per output
-
Sequence 1 is adjustable: delay time from 1 second to 10 minutes
-
Sequences 2 to 6 are adjustable: delay time from 1 second to 1 minute
-
Remote activation via 5-24 VDC, momentary contacts, physical switch contacts
-
Status indicator for each output
-
"EPD" emergency power off port
-
Output link for two TSD-SEQ6 controllers
-
Voltage output for remote LED status display
-
Independent wiring port for each I/O
-
Removable Phoenix-style I/O connectors
-
Power supply sold separately